logo

EZHOU ANJEKA TECHNOLOGY CO.,Ltd Anjeka@anjeka.net 86-0711-5117111

EZHOU ANJEKA TECHNOLOGY CO.,Ltd Company Profile
Cases
Home > Cases >
Company Cases About Water Resistance Performance Comparison: Anjeka6072, 6208, and 578 in Various Formulation Systems

Water Resistance Performance Comparison: Anjeka6072, 6208, and 578 in Various Formulation Systems

2026-03-24
Latest company cases about Water Resistance Performance Comparison: Anjeka6072, 6208, and 578 in Various Formulation Systems

1. Viscosity Reduction Effect

Prepare a water-based resin-free pigment paste and compare the viscosity reduction performance of different dispersants.

2. Effect on Gloss

Add the resin-free pigment paste into different resin systems (water-based alkyd resin, styrene-acrylic emulsion, polyurethane dispersion, and epoxy emulsion) to prepare finished paints.
Apply the paints on test panels using a drawdown bar. After drying, measure the gloss.

3. Effect on Blistering After Water Immersion

After the coated panels are dried, immerse them in water for 7 days. Observe and record the blistering area on the panel surface.

4. Effect on Adhesion After Water Immersion

After water immersion, perform a cross-cut test on the coated panels using a cross-cut tester, followed by tape pull-off.
Observe and record the area of coating detachment.

 

Water-Based Resin-Free Pigment Paste Testing

 

 

Water-Based Resin-Free Pigment Paste Formulations

Carbon Black Paste

Titanium Dioxide Paste (R996)

Material 6072 6208 578 Material 6072 6208 578
Water 50.9 50.9 50.9 Water 20.7 20.7 20.7
Propylene Glycol 2 2 2 Neutralizer DMEA 0.2 0.2 0.2
Dispersant 17.1 17.1 17.1 Dispersant 4.1 4.1 4.1
Carbon Black MA100 30 30 30 Titanium Dioxide R996 75 75 75
Total 100 100 100 Total 100 100 100

 

Preparation Method

After preparing the formulations, add an equal amount of glass beads. Place the mixture in a shaker and shake for 2 hours.

 

latest company case about Water Resistance Performance Comparison: Anjeka6072, 6208, and 578 in Various Formulation Systems  0

Fineness (μm)                                                                 6072                             578                               6208

Water-Based Resin-Free White Paste                            ≤15                               ≤15                                ≤15

Water-Based Resin-Free Black Paste                             ≤15                              ≤15                                 ≤15

 

In both black and white resin-free pigment pastes, Anjeka6072 achieved lower viscosity compared to 6208 and 578, indicating superior viscosity reduction capability.
 

Water-Based Resin-Free Gray Paste Formulation

  6072 578 6208
Water-Based Resin-Free White Paste 10 10 10
Water-Based Resin-Free Black Paste 1 1 1

 

Preparation of Gray Paste

The gray paste was prepared by mixing the white paste and black paste in a ratio of 10:1 (white : black) until a homogeneous mixture was achieved.

 

Gray Paint Formulation
  6072 578 6208
water-based resin 64 64 64
Water 3 3 3

Water-Based Resin-Free Gray Paste

 

33 33 33

 

Mix the water-based resin, water, and gray paste in proportion until homogeneous to obtain the gray paint.

Apply the paint on a sanded tinplate panel at a wet film thickness of 200 μm.

 

Gloss Test After Panel Drying

latest company case about Water Resistance Performance Comparison: Anjeka6072, 6208, and 578 in Various Formulation Systems  1

Conclusion

Anjeka 6072 exhibits gloss performance comparable to 6208 and superior to 578 across different resin systems, with the exception of the styrene-acrylic emulsion system, where it performs slightly less favorably than Xianchuang 578.

Overall, Anjeka 6072 has a minimal impact on gloss.

 

Panel Performance Test After 7 Days of Water Immersion

 

Water-Based Alkyd Resin System

  6072 578 6208

Blistering Area

20% 20% 20%
latest company case about Water Resistance Performance Comparison: Anjeka6072, 6208, and 578 in Various Formulation Systems  2 latest company case about Water Resistance Performance Comparison: Anjeka6072, 6208, and 578 in Various Formulation Systems  3 latest company case about Water Resistance Performance Comparison: Anjeka6072, 6208, and 578 in Various Formulation Systems  4
       

Cross-Cut Adhesion Test

 

 

 

 

 

Detachment Area

<1% <1% <1%
latest company case about Water Resistance Performance Comparison: Anjeka6072, 6208, and 578 in Various Formulation Systems  5 latest company case about Water Resistance Performance Comparison: Anjeka6072, 6208, and 578 in Various Formulation Systems  6 latest company case about Water Resistance Performance Comparison: Anjeka6072, 6208, and 578 in Various Formulation Systems  7

 

Water-Based Alkyd Resin System: No significant difference in water resistance was observed among the three dispersants, with all showing less than 1% blistering and detachment areas.

 

Styrene-Acrylic Emulsion Syste

 

  6072 578 6208
Blistering Area 30% 20% 30%
latest company case about Water Resistance Performance Comparison: Anjeka6072, 6208, and 578 in Various Formulation Systems  8 latest company case about Water Resistance Performance Comparison: Anjeka6072, 6208, and 578 in Various Formulation Systems  9 latest company case about Water Resistance Performance Comparison: Anjeka6072, 6208, and 578 in Various Formulation Systems  10
       

Cross-Cut Adhesion Test

 

 

 

 

 

Detachment Area

15% 15% 15%
latest company case about Water Resistance Performance Comparison: Anjeka6072, 6208, and 578 in Various Formulation Systems  11 latest company case about Water Resistance Performance Comparison: Anjeka6072, 6208, and 578 in Various Formulation Systems  12 latest company case about Water Resistance Performance Comparison: Anjeka6072, 6208, and 578 in Various Formulation Systems  13
 

 

Styrene-Acrylic Emulsion System: 6072 exhibits water resistance comparable to 6208, but slightly inferior to 578.

 

Polyurethane Dispersion System

 

  6072 578 6208
Blistering Area 20% 30% 20%
latest company case about Water Resistance Performance Comparison: Anjeka6072, 6208, and 578 in Various Formulation Systems  14 latest company case about Water Resistance Performance Comparison: Anjeka6072, 6208, and 578 in Various Formulation Systems  15 latest company case about Water Resistance Performance Comparison: Anjeka6072, 6208, and 578 in Various Formulation Systems  16
       

Cross-Cut Adhesion Test

 

 

 

 

 

Detachment Area

<1%
5% <1%
latest company case about Water Resistance Performance Comparison: Anjeka6072, 6208, and 578 in Various Formulation Systems  17 latest company case about Water Resistance Performance Comparison: Anjeka6072, 6208, and 578 in Various Formulation Systems  18 latest company case about Water Resistance Performance Comparison: Anjeka6072, 6208, and 578 in Various Formulation Systems  19
 

 

Polyurethane Dispersion System: 6072 exhibits water resistance comparable to 6208 and superior to 578.

 

Epoxy Emulsion System

  6072 578 6208
Blistering Area 10% 30% 10%
latest company case about Water Resistance Performance Comparison: Anjeka6072, 6208, and 578 in Various Formulation Systems  20 latest company case about Water Resistance Performance Comparison: Anjeka6072, 6208, and 578 in Various Formulation Systems  21 latest company case about Water Resistance Performance Comparison: Anjeka6072, 6208, and 578 in Various Formulation Systems  22
       

Cross-Cut Adhesion Test

 

 

 

 

 

Detachment Area

<1%
5% <1%
latest company case about Water Resistance Performance Comparison: Anjeka6072, 6208, and 578 in Various Formulation Systems  23 latest company case about Water Resistance Performance Comparison: Anjeka6072, 6208, and 578 in Various Formulation Systems  24 latest company case about Water Resistance Performance Comparison: Anjeka6072, 6208, and 578 in Various Formulation Systems  25

 

Epoxy Emulsion System: 6072 demonstrates water resistance comparable to 6208 and superior to 578.

 

Anjeka Water-Based Dispersant 6072

 

latest company case about Water Resistance Performance Comparison: Anjeka6072, 6208, and 578 in Various Formulation Systems  26

Excellent Viscosity Reduction Effect                                 Minimal Impact on Gloss                                              Superior Water Resistance

 

Events
Contacts
Contacts: Ms. Anna
Fax: 86-0711-3809626
Contact Now